How to Perfect Base Preparation to Avoid Wasted Effort
When you invest a significant budget in premium synthetic grass turf and hire professional installers, only to find depressions, water pooling, or large-scale deformation three months later—90% of such failures originate from one underestimated step: base preparation. If synthetic grass turf is the building’s “facade,” then the base is its “structural skeleton.” This article provides an in-depth engineering analysis of base preparation, offering an ultimate solution applicable to any ground condition.
Part 1: Why is the Base the “Invisible Soul”?
1.1 The Three Core Missions of the Base
(1) Load-Bearing and Distribution
– Dynamic loads: Impact forces from foot traffic (approx. 1.5 times body weight)
– Static loads: Continuous pressure from furniture or sports equipment
– Environmental loads: Mechanical effects from rainwater penetration and frost heave
– Data shows: Unprepared bases can settle 3-5cm within 6 months, causing visible undulations
(2) Creating a Drainage Lifeline
– Surface water must flow through: Turf permeable layer → Base filter layer → Subsurface drainage system
– Hazards of poor drainage:
– Standing water breeds mosquitoes (larvae can develop within 48 hours)
– Frost heave damage in winter
– Base mold growth from prolonged dampness (in environments >70% humidity)
(3) Establishing a Stable Geometric Plane
– Flatness tolerance: ≤5mm gap under a 3m straightedge
– Slope deviation: ≤0.5% error over any 10㎡ area
– Micro-roughness: Maximum surface particle size ≤10mm
1.2 Four Typical Symptoms of Base Failure
| Failure Type | Timeframe | Manifestation | Root Cause |
| Localized Settlement | 2-6 months | “Crater-like” depressions | Insufficient compaction (<93% standard) |
| Drainage Failure | First rainfall | Regional ponding | Reverse slope or slope <0.3% |
| Edge Heaving | 1-2 seasonal cycles | Edge lifting 3-10cm | No buffer space for thermal expansion |
| Microbial Damage | 6-12 months | Mold spots, odors at base | Missing moisture barrier + poor ventilation |